移机步骤 Moving steps 1.确定空调移动的位置,管度的长度是否足够。空调的安放位置是否适合,是否符合各种要求等。空调的重新移机也是需要符合一般安装空调位置的要求的。应该勘察好环境位置是否适合转移空调,再准备好需要的材料和器材。包括制冷修理工具一套,以及室内外机的固定用膨胀螺丝等材料。还有需要更新、延长等的管道等等。 1. determine the position of the air conditioning, the length of the tube is sufficient. Whether the placement of air conditioning is suitable, whether it meets the requirements and so on. The new machine air conditioning also need to meet the general requirements of the location of the installation of air conditioning. It is necessary to find out whether the environment is suitable for the transfer of air conditioning, and to prepare the materials and equipment needed. It includes a set of refrigeration repair tools and a fixed expansion screw for indoor and outdoor machines. There are also pipes that need to be updated, extended and so on. 2.回收制冷剂:把空调器中的制冷剂收集到室外机中去。拆机前应启动空凋器,可用遥控器设定制冷状态,待压缩机运转5-10分钟,制冷状态正常后,用扳手拧下外机的液体管与气体管接口上的保帽,关闭高压管(细)的截止阀门,l分钟后管外表结露,立即关闭低压管(粗)截止阀门,同的迅速关机,拔下电源插头,用扳手拧紧保险帽,至此回收制冷剂工作完成。也可采用室内机上的强制启动按钮开机,同的观察室内、外机是否还有其他故障。避免移机后带来麻烦。 2. recycle refrigerant: collect the refrigerant in the air conditioner to the outdoor machine. Before start the air conditioner to disassemble, use the remote control to set the cooling condition, the operation of the compressor refrigeration after 5-10 minutes, the normal state, with the wrench under the machine liquid tube protective cap on the interface with the gas pipe, close the high-pressure tube (fine) cut-off valve, l minutes after the tube surface condensation, close the low pressure tube immediately (coarse) cut-off valve, with rapid shutdown, unplug the power plug, use a wrench to tighten safety cap, thus recovering refrigerant work. It can also use the forced start button on the indoor machine, and whether there are other faults in the same observation room and the outside machine. After moving to avoid trouble. 3.切断电源,观察外机有无障碍物,取下内机机罩,清理外机附近的物品。打开室内机壳观察内机过滤网有无灰尘及异味,清理过滤网等。 3. cut off the power supply, observation machine has no obstacle, remove the machine hood, clean up outside the nearby items. Open the indoor machine shell observation machine filter network has no dust and odor, cleaning filter net and so on. 4.制冷剂回收后,可拆卸室内机。用扳手把室内机连接锁母拧开,用准备好的密封钠子旋好护住室内机连接接头的丝纹,防止在搬运中碰坏接头丝纹;再用十字起拆下控制线。同时应做标记,避免在安装时接错。如果信号线或电源线接错,会造成外机不运转,或机器不受控制。内机挂板一般固定的比较牢固,卸起来比较困难;卸完取下挂板,置于平面水泥地再轻轻拍平、校正。 After 4. refrigerants are recovered, the indoor machine can be dismantled. With the wrench, turn the indoor machine to the lock nut, and use the ready sealed sodium button to protect the wire pattern of the connection of the indoor machine, so as to prevent the wire thread from breaking in the transportation, and then remove the control line from the cross. At the same time, the mark should be made to avoid the error during installation. If the signal line or the power line is wrong, it will cause the machine to not operate, or the machine is not controlled. In general machine hanging plate fixed firmly, it is difficult to finish unloading unloading; removing the hanging plate, placed on a flat cement then patted down, correction. 5.拆室外机具有风险,请务必在有专业空调制冷维修工作人员的安全拆卸保证下拆卸。拧开外机连接锁母后,应用住备好的密封钠子旋好护往外机连接接头的丝纹。再用扳手松开外机底脚的固定螺丝。拆卸后放下室外机时,最好用绳索吊住,卸放的同时应注意平衡,避免振动、磕碰,并注意安全。应慢慢捋直室外空调器的接管,用准备好的四个堵头封住连接管的四个端口,防止空气中灰尘和水份进入。堵头上好,最后再用塑料袋扎好,盘好以便于搬运。 5. dismantling the outdoor machine has the risk, please be sure to disassemble under the safe dismantling guarantee of the professional air conditioning and refrigeration maintenance staff. Unscrew the machine is connected with the lock mother, prepare a good sealing application to support good sodium sub rotary machine joint thread. Fixed screw wrench loosen machine feet. After the demolition of the outdoor machine down, preferably with rope, and discharge the balance should be paid attention to, avoid vibration, bump, and Caution. We should slowly straighten out the takeover of the outdoor air conditioner and seal the four ports of the connecting pipe with four prepared plugs to prevent dust and water from entering the air. It is good to plug the head, and then the plastic bag is lash up at the end, and the plate is good for easy handling. 6.清理拆卸后的空调位置。清理空调的内外部。准备重新安装空调。 6. clean up the disassembled air conditioning position. Clean the inner and outer parts of the air conditioner. Be ready to reinstall the air conditioner. 7.先安装好内机挂板,待外机与内机挂板安装牢固以后,再把连接管捋平直,查看管道是否有弯瘪现象;接下来应检查两端喇叭口是否有裂纹,如有裂纹,应重新扩口,否则会漏氟。最后,检查控制线是否有短路、断路现象,在确定管路、控制线、出水管良好后,把它们绑扎在一起并将连接管口密封好。过墙时应两个人在墙内、外配合缓慢穿出,避免拉伤;连接好管道与内、外机,并接好控制线。接下去,排除管道和内机中的空气。方法是这样; 7., first install the inner machine hanging plate. After installing the external machine and the hanging plate of the internal machine firmly, then connect the connecting pipe straight to see if the pipeline is deflated or deflated. Next, check whether there is any crack on the bell mouth at both ends. If there is a crack, it should expand again, otherwise it will leak away the fluorine. Finally, check whether there is short circuit or open circuit in the control line. After determining the pipeline, control line and outlet pipe is good, tie them together and seal the connection ports. The wall should be two people in the inner and outer wall with slow out to avoid injury; connecting pipe and the inner and outer machine, and connect the control line. Next, remove the air from the pipe and the inner machine. This is the way it is. (1)把连接好的外机接头拧紧(细),用专用扳手松开截止阀门的阀杆1圈左右; (1) tighten (fine) the connection of the joint, and use a special wrench to unlock the valve stem of the cut-off valve about 1 circles. (2)听到外机接头(粗)吱吱响声,30 秒左右,用钣手拧紧(粗)接头; (2) heard outside the machine joint (coarse) creak, about 30 seconds, with a wrench tighten (coarse) joint; (3)松开(粗)管上戴止阀门的阀杆; (3) the valve stem of the valve on the loosened (coarse) pipe; (4)彻底松开(细)管上截止阀门的阀杆。这时空凋器排空结束。 (4) completely unlock the valve stem of the upper cut-off valve on the (fine) tube. The space-time withered end is emptied. 最后,用洗涤剂进行检漏,仔细观察每一个接头有无气泡冒出,验明系统确无泄漏后,旋紧阀门保险帽,即可开机试运行。 Finally, leak with detergent, careful observation of each joint has no bubbles, no leakage check system, tighten the valve safety cap, can start trial operation. 8.在确保电压、电源符合规定的供应后,插电等3-5分钟,将遥控器设置在制冷模式,温度设定在最低的条件下,开机运行(最好在中午和下午试机)。空调运行后,将遥控器的风速开关设定在不同的档位上运行,观察内机有无异常噪音。开机运行15分钟左右观察外机风扇是否运转正常,外机有无异常噪音。开机运行 30分钟左右观察室内机出风有无冷风感,室外机出水管有无冷凝水流出,流水是否畅通。 8., in order to ensure that the voltage and power supply is in line with the prescribed supply, after plugging for 3-5 minutes, the remote controller is set in the refrigeration mode, and the temperature is set at the lowest condition, and the operation is started (preferably at noon and afternoon). After the operation of the air conditioner, the wind speed switch of the remote control is set on different gear positions, and there is no abnormal noise in the inner machine. Open the machine for 15 minutes or so to observe whether the fan is operating normally, and there is no abnormal noise in the outer machine. Open the machine for 30 minutes or so to observe the cold wind in the indoor air, the outflow of condensate water in the outdoors and the flow of water. 9.检查各种电流、电压是否符合空调的运行标准。 9. check whether the current and voltage are in accordance with the operating standards of the air conditioning. 10.空调移机的正常情况下可以不用加氟。如有需要可以一起加氟。如何加氟可以参见品牌空调网之前详细的介绍以及相关文章。 10. under the normal air conditioning can not add fluoride. If there is a need to add fluorine together. How to add fluorine can be described in detail before the brand air conditioning network and related articles. 品牌空调网特别注意提醒:空调的移机程序复杂,本文提供让用户参考移机的操作的了解。但移动空调请找专业的空调安装维修人员来代劳。因为移动空调带有一定的危险性。并不适宜没有资格证的用户单独移动空调。 Air conditioning brand network special attention reminder: air conditioning moves in this complex program, let users reference machine operation knowledge. But please find a professional mobile air-conditioning air-conditioning installation and maintenance personnel. Because the mobile air conditioning has a certain risk. It is not appropriate for a user without a qualification to move the air conditioner alone. 空调移机注意事项: Air conditioning precautions: 1.确保安装的地方是能符合安装空调的要求的,特别是稳固空调的室外机和室内机。两机之间的连接要密封,距离要短。确保转移的电线连接合格。 1. to ensure that the installation is in line with the requirements of the installation of air conditioning, especially the outdoor and indoor air conditioners. The connection between the two machines should be sealed and the distance is short. Ensure that the transfer of wire connection is qualified. 2.排水管安装不合理,而致冷凝水无法排出,或者内机安装不平衡而引起冷凝水无法排出,排水管接头脱落、 2. drainage pipe installation is not reasonable, and the condensation water can not be discharged, or the internal machine installation is not balanced and cause the condensation water can not be discharged, drain pipe joint fall off, |
上一页 空调移机步骤 |
下一页 空调不制冷加氟多少钱?制冷效果差如何解决? |